Power Backup (Prolink)

Master II Series (3P/3P)

PROLiNK Master II Series (3P/3P) Tower Type is a three-phase output UPS system that employs a true online double-conversion technology. A Digital Signal Processor (DSP) technology digitizes the data and mathematically manipulates them to provide an improved solution with higher performance and reliability.

Category: Power Backup (Prolink) Tags: power backup, ups
Product categories
  • Active Lightning Rod (KALRE)
  • Addressable Devices & Accessories (Secutron)
  • Addressable Fire Alarm Control Panel (Secutron)
  • AI Platform by NETIX
  • CCTV Security System (Honeywell Security)
  • Conventional Devices & Accessories (Secutron)
  • Conventional Fire Alarm Control Panel (Secutron)
  • E-Plus Exothermic Welding (Sunlight)
  • Exothermic Welding & Grounding System (Goldweld)
  • Fire Detection & Alarm System (Ansorl)
  • Fire Pro Valves (APC Industries)
  • Flow Measurement and Controls (Badger Meter)
  • Intelligent Building Management System (Honeywell)
    • BTU / Flow / Water Meter
    • Direct Digital Controllers
    • Manual Valves
    • Sensors & Switches
    • Software
    • Thermostats
    • Valves & Actuators
  • Power Backup (Prolink)
  • Description

Master II Series (3P/3P)-Tower

 

MODEL

PRO83310-QS/QL 10KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
3-phase in / 1-phase out
1-phase in / 1-phase out
Rating (VA) 10000VA
Nominal Power (W) 10000W
Standard Model

Dimension (mm)

630 x 250x 826 (D x W x H)
Weight (kg) 124
Long-run Model

Dimension (mm)

630 x 250 x 826 (D x W x H)
Weight (kg) 28

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Standard Model

Type

12V Lead Acid
Numbers (10+10)pcs x 1 string
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on customer
Numbers (10+10)pcs
Charging Current (max) 1~12A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

PRO83320-QS/QL 20KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
3-phase in / 1-phase out
1-phase in / 1-phase out
Rating (VA) 20000VA
Nominal Power (W) 20000W
Standard Model

Dimension (mm)

630 x 250x 826 (D x W x H)
Weight (kg) 139
Long-run Model

Dimension (mm)

630 x 250 x 826 (D x W x H)
Weight (kg) 43

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Standard Model

Type

12V Lead Acid
Numbers (16+16)pcs x 1 string
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on customer
Numbers (16+16) or (18+18) or (20+20)pcs
Charging Current (max) 1~12A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

PRO83330-QS/QL 30KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
Rating (VA) 30000VA
Nominal Power (W) 30000W
Standard Model

Dimension (mm)

815 x 300 x 1000 (D x W x H)
Weight (kg) 225
Long-run Model

Dimension (mm)

815 x 300 x 1000 (D x W x H)
Weight (kg) 60

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Standard Model

Type

12V Lead Acid
Numbers (16+16)pcs x 2 strings
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on customer
Numbers (16+16) or (18+18) or (20+20)pcs
Charging Current (max) 1~12A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

PRO83340-QS/QL 40KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
Rating (VA) 40000VA
Nominal Power (W) 40000W
Standard Model

Dimension (mm)

815 x 300 x 1000 (D x W x H)
Weight (kg) 250
Long-run Model

Dimension (mm)

815 x 300 x 1000 (D x W x H)
Weight (kg) 67

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Standard Model

Type

12V Lead Acid
Numbers (16+16)pcs x 2 strings
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on customer
Numbers (16+16) or (18+18) or (20+20)pcs
Charging Current (max) 1~16A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

PRO83360-QL 60KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
Rating (VA) 60000VA
Nominal Power (W) 60000W
Dimension (mm) 790 x 360 x 1010 (D x W x H)
Weight (kg) 108

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Type Depending on the application
Numbers (16+16) or (18+18) or (20+20)pcs
Charging Current (max) 2~24A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

PRO83380-QL 80KVA

GENERAL

UPS Type Tower
Phase 3-phase in / 3-phase out
Rating (VA) 80000VA
Nominal Power (W) 80000W
Dimension (mm) 790 x 360 x 1010 (D x W x H)
Weight (kg) 113

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

MANAGEMENT

Smart RS-232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and Mac
Optional SNMP Power management from SNMP manager and web browser

BATTERY

Type Depending on customer
Numbers (16+16) or (18+18) or (20+20)pcs
Charging Current (max) 2~24A Adjustable

REAR PANEL

1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port*
5. Parallel port**
6. Intelligent slot
7. External battery connector/terminal*** (for both standard and long-run models)
8. Line input circuit breaker/switch
9. Maintenance bypass switch
10. Bypass input circuit breaker/switch
11. Output circuit breaker/switch
12. Line input terminal
13. Bypass input terminal
14. Output terminal

Related products

Titan Series (3P/3P)
Quick View

Power Backup (Prolink)

Titan Series (3P/3P)

Professional II Series (1P/1P)
Quick View

Power Backup (Prolink)

Professional II Series (1P/1P)

Master II Series (1P/1P) – Rack/Tower Lithium-ion Battery
Quick View

Power Backup (Prolink)

Master II Series (1P/1P) – Rack/Tower Lithium-ion Battery

Titan Plus Series (3P/3P)
Quick View

Power Backup (Prolink)

Titan Plus Series (3P/3P)

Giant I Series (3P/3P)
Quick View

Power Backup (Prolink)

Giant I Series (3P/3P)

Follow us on social media!

Copyright 2026 © FlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact

Login

Lost your password?