MODEL
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 120KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
2 |
Dimension (mm) | 1100 x 600 x 1475 (D x W x H) |
Weight (kgs) | 308 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 180KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
3 |
Dimension (mm) | 1100 x 600 x 1475 (D x W x H) |
Weight (kgs) | 352 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 300KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
5 |
Dimension (mm) | 1100 x 600 x 2010 (D x W x H) |
Weight (kgs) | 516 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 420KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
7 |
Dimension (mm) | 1100 x 600 x 1475 (D x W x H) |
Weight (kgs) | 654 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 480KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
8 |
Dimension (mm) | 1065 x 1000 x 2000 (D x W x H) |
Weight (kgs) | 932 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |
GENERAL
Phase |
3-phase in / 3-phase out |
Cabinet Capacity | 600KW |
Battery Type |
External Battery |
One Power Module Capacity | 60KVA / 60KW |
Max. Power Module Number |
10 |
Dimension (mm) | 1065 x 1000 x 2000 (D x W x H) |
Weight (kgs) | 1020 |
INPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Range | -30% ~ +20% |
Nominal Frequency |
50/60Hz (Auto Sensing) |
Frequency Range | 40Hz ~70Hz |
Power Factor | > 0.99 at 100% load
>0.98 at 50% load |
Harmonic Distortion (THDi) | < 3% @ 100% load |
OUTPUT
Nominal Voltage | 3 x 380 / 400 / 415VAC (3Ph+N) |
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load)
≦ ± 2% Typical (unbalanced load) |
Nominal Frequency | 50/60Hz |
Frequency Range (Synchronized) | 46~54Hz or 56~64Hz |
Overload Capability | 1 hour for 110%,
10 mins for 111%~125%, 1 min for 126%~150% and 200ms for >150% |
Harmonic Distortion | ≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load) |
Efficiency | 96% |
MANAGEMENT
Smart RS-232 / USB |
Supports Windows® family, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
BATTERY
Nominal Voltage | ±192V ~ ±240V (Selectable) |
Maximum Voltage | ±240V (12V x 40 Pcs) |
Minimum Voltage | ±192V (12V x 32 Pcs) |
Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) |
Boost Charging Voltage | 2.35V/Cell |
Temperature Compensation | Yes |
Maximum Charging Current (Per Power Module) | 18A (Adjustable) |