MODEL
PRO901-WS/WL SERIES 1KVA
GENERAL
UPS Type | Tower |
Phase | Single phase with ground |
Rating (VA) | 1000 |
Nominal Power (W) | 800 |
Standard Model Dimension (mm) | 282 x 145 x 220 (D x W x H) |
Weight (kg) | 9.8 |
Long-run Model Dimension (mm) | 282 x 145 x 220 (D x W x H) |
Weight (kg) | 4.1 |
INPUT
Connection Type | IEC 320-C14 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%) 160-280 VAC (Load at 100%) |
Frequency Range | 45 ~ 70 Hz |
Power Factor | >= 0.99 |
OUTPUT
Connection Type | 3 x Universal socket (PRO901WS) 2 x Universal socket (PRO901WL) |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load) ≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232* USB Port |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 2 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Number | 2 or 3 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input 2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles |
PRO902-WS/WL SERIES 2KVA
GENERAL
UPS Type | Tower |
Phase | Single phase with ground |
Rating (VA) | 2000 |
Nominal Power (W) | 1600 |
Standard Model Dimension (mm) | 397 x 145 x 220 (D x W x H) |
Weight (kg) | 17 |
Long-run Model Dimension (mm) | 397 x 145 x 220 (D x W x H) |
Weight (kg) | 6.8 |
INPUT
Connection Type | IEC 320-C14 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%) 160-280 VAC (Load at 100%) |
Frequency Range | 45 ~ 70 Hz |
Power Factor | >= 0.99 |
OUTPUT
Connection Type | 3 x Universal socket (PRO902WS) 2 x Universal socket (PRO902WL) |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load) ≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232* USB Port |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 4 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Number | 4 / 6 / 8 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input 2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles |
PRO903-WS/WL SERIES 3KVA
GENERAL
UPS Type | Tower |
Phase | Single phase with ground |
Rating (VA) | 3000 |
Nominal Power (W) | 2400 |
Standard Model Dimension (mm) | 421 x 190 x 318 (D x W x H) |
Weight (kg) | 27.6 |
Long-run Model Dimension (mm) | 397 x 145 x 220 (D x W x H) |
Weight (kg) | 7.4 |
INPUT
Connection Type | IEC 320-C20 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%) 160-280 VAC (Load at 100%) |
Frequency Range | 45 ~ 70 Hz |
Power Factor | >= 0.99 |
OUTPUT
Connection Type | 4 x Universal socket (PRO903WS) 2 x Universal socket (PRO903WL) Terminal |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load) ≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232* USB Port |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 6 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Number | 6 / 8 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input 2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles 8. Output circuit breaker 9. Output terminal |
PRO906-WS/WL SERIES 6KVA
GENERAL
UPS Type | Tower |
Phase | Single phase with ground |
Rating (VA) | 6000 |
Nominal Power (W) | 4800 |
Standard Model Dimension (mm) | 369 x 190 x 688 (D x W x H) |
Weight (kg) | 61 |
Long-run Model Dimestions (mm) | 369 x 190 x 318 (D x W x H) |
Weight (kg) | 12 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240VAC |
Voltage Range | 110-300 VAC (Load at 50%) 176-300 VAC (Load at 100%) |
Frequency Range | 46~54 Hz or 56~64 Hz |
Power Factor | >= 0.99 |
OUTPUT
Connection Type | Terminal |
Output Voltage | 208/220/230/240VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
Frequency Range (Batt. Mode) | 50Hz or 60Hz +/-0.1Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load) ≤5% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232* USB Port Emergency Power Off (EPO) |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 9 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Number | 16 ~20 (Adjustable) |
Charging Current (max) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
REAR PANEL
|
PRO910-WS/WL SERIES 10KVA
GENERAL
UPS Type | Tower |
Phase | Single phase with ground |
Rating (VA) | 10000 |
Nominal Power (W) | 8000 |
Standard Model Dimension (mm) | 442 x 190 x 688 (D x W x H) |
Weight (kg) | 66 |
Long-run Model Dimestions (mm) | 442 x 190 x 318 (D x W x H) |
Weight (kg) | 16 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240VAC |
Voltage Range | 110-300 VAC (Load at 50%) 176-300 VAC (Load at 100%) |
Frequency Range | 46~54 Hz or 56~64 Hz |
Power Factor | >= 0.99 |
OUTPUT
Connection Type | Terminal |
Output Voltage | 208/220/230/240VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
Frequency Range (Batt. Mode) | 50Hz or 60Hz +/-0.1Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load) ≤5% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232* USB Port Emergency Power Off (EPO) |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 9 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Number | 16 ~ 20 (Adjustable) |
Charging Current (max) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
REAR PANEL
|