Skip to content
FlexNet System IncorporatedFlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact
Conventional Devices & Accessories (Secutron)

INX-10A – NAC EXPANDER / POWER SUPPLY

The INX-10A NAC Expander / Power Supply works with UL/ULC 24 VDC Listed compatible Intelligent fire alarm control panels.

Category: Conventional Devices & Accessories (Secutron)
Product categories
  • Active Lightning Rod (KALRE)
  • Addressable Devices & Accessories (Secutron)
  • Addressable Fire Alarm Control Panel (Secutron)
  • AI Platform by NETIX
  • CCTV Security System (Honeywell Security)
  • Conventional Devices & Accessories (Secutron)
  • Conventional Fire Alarm Control Panel (Secutron)
  • E-Plus Exothermic Welding (Sunlight)
  • Exothermic Welding & Grounding System (Goldweld)
  • Fire Detection & Alarm System (Ansorl)
  • Fire Pro Valves (APC Industries)
  • Flow Measurement and Controls (Badger Meter)
  • Intelligent Building Management System (Honeywell)
    • BTU / Flow / Water Meter
    • Direct Digital Controllers
    • Manual Valves
    • Sensors & Switches
    • Software
    • Thermostats
    • Valves & Actuators
  • Power Backup (Prolink)
  • Description

The INX-10A NAC Expander / Power Supply works with listed compatible Intelligent fire alarm control panels. Available in a 10 Amp configuration, the INX-10A can extend the power capabilities of existing notification appliance circuits as well as provide power for other ancillary devices. In addition, the INX-10A has the ability to operate with any UL/ULC Listed 24 VDC fire alarm control panel to provide Notification Appliance Circuit expansion.

The INX-10A NAC Expander / Power Supply is equipped with five individual Class B (Style Y) or Class A (Style Z) output circuits that can be independently configured for NAC operation or auxiliary power. The INX-10A provides the option of configuring all five circuits as an output to provide general-purpose power.

In addition output circuits four and five can be configured to provide auxiliary power for four-wire detectors or door holders. Each output circuit is rated for 2.5 Amps.

When configured for NAC operation the INX-10A r outputs can be set for Steady, Temporal Code, California Code or March Time. In addition, the output circuits have field-selectable built-in strobe and horn synchronization protocols to support Amseco, System Sensor, Wheelock and Gentex devices, eliminating the need for additional external synchronization modules.

Features
• 10 Amp output
• 120 / 240V operation
• Works with listed compatible Series Intelligent Fire Alarm Control Units
• Easily configured using DIP switches
• One isolated input from the host panel
• Five Class B (Style Y) or Class A (Style Z) synchronized output circuits
• DC regulated outputs
• Configurable AC Power fail delay
• Ground fault enable or disable
• Option available on the configuration to enable or disable the battery charger on the activation
• From 7 to 15 Address functions (Combination of inputs and outputs, depending on the application)
• Outputs individually controllable
• Separate Relay for Ground Fault and Common Trouble available on terminals
• Horn/Strobe synchronization protocols include Amseco, Gentex, System Sensor and Wheelock
• Two-wire horn/strobe Sync Mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate
• Audible signals may be configured for Steady, Temporal Code, California Code and March Time
• Output circuits four and five can be configured to provide auxiliary power for four-wire detectors or door holders.
• Canadian two-stage operation
• Output fault notification to fire alarm control panel
• Ability to sync outputs for multiple INX-10A units
• 2.5 Amp max. current per output
• 1.7 Amp auxiliary power output
• Built-in charger for sealed lead acid or gel type batteries
• Unit includes power supply, charger, red door, black backbox, transformer and battery leads
• Compatible with any UL/ULC listed 24VDC conventional fire alarm control panel to provide Notification Appliance Circuit expansion

Related products

MMX-BB-1001R Semi-Flush Backbox for Series 1000 Annunciators
Quick View

Conventional Devices & Accessories (Secutron)

MMX-BB-1001R Semi-Flush Backbox for Series 1000 Annunciators

MHD-65-200 Mircom Series 65 Plug in Heat Detector 200 Degrees
Quick View

Conventional Devices & Accessories (Secutron)

MHD-65-200 Mircom Series 65 Plug in Heat Detector 200 Degrees

MS-703U Series Single Action Emergency Station
Quick View

Conventional Devices & Accessories (Secutron)

MS-703U Series Single Action Emergency Station

AGD-048 ADDER GRAPHIC DRIVER MODULE
Quick View

Conventional Devices & Accessories (Secutron)

AGD-048 ADDER GRAPHIC DRIVER MODULE

SP SERIES SPEAKERS
Quick View

Conventional Devices & Accessories (Secutron)

SP SERIES SPEAKERS

RAXN-LCD - NETWORK REMOTE ANNUNCIATOR
Quick View

Conventional Devices & Accessories (Secutron)

RAXN-LCD – NETWORK REMOTE ANNUNCIATOR

MH-25 SERIES
Quick View

Conventional Devices & Accessories (Secutron)

MH-25 SERIES

MHD-65-135 Mircom Series 65 Plug in Heat Detector 135 Degrees
Quick View

Conventional Devices & Accessories (Secutron)

MHD-65-135 Mircom Series 65 Plug in Heat Detector 135 Degrees

Follow us on social media!

Copyright 2025 © FlexNet System Incorporated