Used in most general flow measuring applications in metallic or non-metallic pipes.
- Cost savings over other systems offered on the market today
- Impeller, bearing, and shaft are easily replaced in the field without changing the calibration
- Impeller shape coupled with the absence of magnetic drag provides accuracy and repeatability
-
Temperature RatingsStandard Version: 221 °Fcontinuous service
High-Temperature Version: 285 °F continuous services; 305 °F peak temperature (limited duration) -
Pressure RatingsAt 100° F: 400 PSI
At 300° F (High-Temperature Version Only): 325 psi -
Recommended Design Flow Range0.5…30 ft/sec Initial detection below 0.3 ft/sec
-
Accuracy± 1.0% of full scale over the recommended design flow range
-
Repeatability± 0.3% of full scale over the recommended design flow range
-
Linearity± 0.2% of full scale over the recommended design flow range
-
Transducer ExcitationSupply voltage = 8V DC min. 35V DC max.
Quiescent current = 600 µA (typical)
OFF State (VHigh) = Supply voltage – (600 µA * Supply impedance)
ON State (VLow) = 1.2V DC @ 40 mA (15 Ω + 0.7V DC) -
Output Frequency3.2…200 Hz
-
Output Pulse Width5 msec ±25%
-
Electrical Cable for Standard Sensor Electronics20 ft (6 m) of 2-conductor 20 AWG shielded UL type PTLC wire provided for connection to display or analog transmitter unit. Rated to 221° F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for the application.
-
Electrical Cable for IR Sensor Electronics48 in. (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).