Skip to content
FlexNet System IncorporatedFlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact
Fire Detection & Alarm System (Ansorl)

HD105 Heat Detector

Product Features:
Operating Voltage Range: 9 to 28VDC Volts Non-polarized

Standby Current: 60μA @ 24 VDC
Installation Temperatures: -10°C to50°C

Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Maximum Alarm Current (LED on: ) ≤ 30mA @ 24 VDC
Fixed Temperature Rating: 57°C

Height: 48mm installed in Base
Diameter: 99mm
Weight: 155g

Category: Fire Detection & Alarm System (Ansorl)
Product categories
  • Active Lightning Rod (KALRE)
  • Addressable Devices & Accessories (Secutron)
  • Addressable Fire Alarm Control Panel (Secutron)
  • AI Platform by NETIX
  • CCTV Security System (Honeywell Security)
  • Conventional Devices & Accessories (Secutron)
  • Conventional Fire Alarm Control Panel (Secutron)
  • E-Plus Exothermic Welding (Sunlight)
  • Exothermic Welding & Grounding System (Goldweld)
  • Fire Detection & Alarm System (Ansorl)
  • Fire Pro Valves (APC Industries)
  • Flow Measurement and Controls (Badger Meter)
  • Intelligent Building Management System (Honeywell)
    • BTU / Flow / Water Meter
    • Direct Digital Controllers
    • Manual Valves
    • Sensors & Switches
    • Software
    • Thermostats
    • Valves & Actuators
  • Power Backup (Prolink)
  • Description

AS-HD105 Heat detectors are photo-electronic detector uses a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

The detector that initiated the alarm condition will have its red LED and relays latched until reset by the panel.

Heat detector and smoke & heat detector combine a photoelectronic sensing chamber and a temperature heat detector.

Related products

CFP-16 Fire Alarm Control Panel
Quick View

Fire Detection & Alarm System (Ansorl)

CFP-16 Fire Alarm Control Panel

MCP-2D Manual Call Point
Quick View

Fire Detection & Alarm System (Ansorl)

MCP-2D Manual Call Point

New
MCP-EW Manual Call Point Weather-proof Enclosure
Quick View

Fire Detection & Alarm System (Ansorl)

MCP-EW Manual Call Point Weather-proof Enclosure

SSG-03 Strobe Sounder
Quick View

Fire Detection & Alarm System (Ansorl)

SSG-03 Strobe Sounder

New
MN3010 Addressable 1 Loop Fire Alarm Control Panel
Quick View

Fire Detection & Alarm System (Ansorl)

MN3010 Addressable 1 Loop Fire Alarm Control Panel

SD102 Smoke Detector
Quick View

Fire Detection & Alarm System (Ansorl)

SD102 Smoke Detector

AIO Input and Output Module
Quick View

Fire Detection & Alarm System (Ansorl)

AIO Input and Output Module

Fire System Power Supply Box
Quick View

Fire Detection & Alarm System (Ansorl)

Fire System Power Supply Box

Follow us on social media!

Copyright 2025 © FlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact

Login

Lost your password?