Skip to content
FlexNet System IncorporatedFlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact
Fire Detection & Alarm System (Ansorl)

AIO Input and Output Module

The AS-AIO I/O module (AS-AIO module for short) is used with a two-bus linkage fire alarm control system.

It is mainly used to realize an output control for fire linkage equipment (such as smoke dampers, blow valves and fire dampers) and receive the feedback signals of the fire linkage equipment so that a judgment on whether or not the fire linkage equipment is operating normally can be done.

Category: Fire Detection & Alarm System (Ansorl)
Product categories
  • Active Lightning Rod (KALRE)
  • Addressable Devices & Accessories (Secutron)
  • Addressable Fire Alarm Control Panel (Secutron)
  • AI Platform by NETIX
  • CCTV Security System (Honeywell Security)
  • Conventional Devices & Accessories (Secutron)
  • Conventional Fire Alarm Control Panel (Secutron)
  • E-Plus Exothermic Welding (Sunlight)
  • Exothermic Welding & Grounding System (Goldweld)
  • Fire Detection & Alarm System (Ansorl)
  • Fire Pro Valves (APC Industries)
  • Flow Measurement and Controls (Badger Meter)
  • Intelligent Building Management System (Honeywell)
    • BTU / Flow / Water Meter
    • Direct Digital Controllers
    • Manual Valves
    • Sensors & Switches
    • Software
    • Thermostats
    • Valves & Actuators
  • Power Backup (Prolink)
  • Description

Product Features:

1. Mode of operation: Nonpolar two-wire system
2. Quiescent current: <0.6mA (power-down mode)
3. Action current: <10mA
4. Capacity of the output control contact: 2A@DC30V
5. Operation indicator: The inspection indicator will blink once about every 12 seconds in the inspection status or remain lit in the output status; the input indicator will remain lit in the feedback status.
6. Operating environment: Temperature: - 10℃ ~ 50 ; relative humidity: ≤95% ( ℃ 40 ±2 ℃ ℃, without condensation)
7. Terminal load: 47K resistance
8. External dimensions: 86×86×40(mm)
9. Weight: about 130g
10. Executive standard: EN54-18

Related products

New
GST102 Infrared Reflective Beam Smoke Detector
Quick View

Fire Detection & Alarm System (Ansorl)

GST102 Infrared Reflective Beam Smoke Detector

SHD109 Smoke/Heat Combined Detector
Quick View

Fire Detection & Alarm System (Ansorl)

SHD109 Smoke/Heat Combined Detector

AIM Input Module
Quick View

Fire Detection & Alarm System (Ansorl)

AIM Input Module

ASH107 Addressable Smoke and Heat Combined Detector
Quick View

Fire Detection & Alarm System (Ansorl)

ASH107 Addressable Smoke and Heat Combined Detector

New
MCP-EW Manual Call Point Weather-proof Enclosure
Quick View

Fire Detection & Alarm System (Ansorl)

MCP-EW Manual Call Point Weather-proof Enclosure

MCP-05 Manual Pull Station
Quick View

Fire Detection & Alarm System (Ansorl)

MCP-05 Manual Pull Station

AHD105 Addressable Heat Detector
Quick View

Fire Detection & Alarm System (Ansorl)

AHD105 Addressable Heat Detector

Bell-6 Fire Bell
Quick View

Fire Detection & Alarm System (Ansorl)

Bell-6 Fire Bell

Follow us on social media!

Copyright 2026 © FlexNet System Incorporated
  • Home
  • Products
  • About Us
  • Partners
  • Contact

Login

Lost your password?